Firefighting Pump Sets

Firefighting Pump Sets (TF-FFS). Proposed catalog envelope: 50–5,000 gpm (11–1,136 m³/h); 50–250 m / ~5–25 bar. Final selection is project-specific.

Specifications

Firefighting Pump Sets

Model TF-FFS
Pump Type Packaged firefighting pump set with main pump(s), jockey pump and controls
Nominal Size Range Typical 2 in to 12 in; larger engineered
Flow Range 50–5,000 gpm (11–1,136 m³/h)
Head 50–250 m / ~5–25 bar
Pressure Rating Selected to fire-system duty
Temperature Ambient clean fire-water
Connection Flanged suction/discharge manifolds

Materials

Materials of Construction

Casing: Cast iron / ductile iron / carbon steel depending pump; Impeller: Bronze / stainless steel; Shaft: Stainless/alloy steel

Final metallurgy, shaft material, wear components, elastomers and seal arrangement are selected to suit the pumped liquid, temperature, pressure and project specification.

Applications

Typical Applications

  • Fire Water
  • Buildings
  • Industrial
  • Oil & Gas
  • Infrastructure

Standards

Standards

NFPA 20 configuration available; UL/FM only when specifically quoted/applicable; Local fire-code requirements

Compliance, listing or certification applies only when specifically included in the selected model and quotation.

Downloads

TF-FFS Technical Downloads

Documents are published when available for the selected configuration.

Firefighting Pump Sets

TF-FFS is a TexasFlow series for fire water, buildings, industrial applications.

Key Features

  • Packaged firefighting pump set with main pump(s), jockey pump and controls
  • Size: Typical 2 in to 12 in; larger engineered
  • Flow: 50–5,000 gpm (11–1,136 m³/h)
  • Head: 50–250 m / ~5–25 bar
  • Configurable materials and sealing
  • Curves, drawings and test documentation available for selected configuration

Selection note: Published ranges are proposed catalog envelopes. Final model, duty point, NPSHr, motor power, pressure class, metallurgy and certification must be confirmed against approved manufacturer data.

Size

Typical 2 in to 12 in; larger engineered

Pressure Rating

Selected to fire-system duty

Material

Casing: Cast iron / ductile iron / carbon steel depending pump; Impeller: Bronze / stainless steel; Shaft: Stainless/alloy steel

Standard

NFPA 20 configuration available; UL/FM only when specifically quoted/applicable; Local fire-code requirements

Flow Rate

50–5, 000 gpm (11–1, 136 m³/h)

Head

50–250 m / ~5–25 bar

Connection Type

Flanged suction/discharge manifolds

Temperature

Ambient clean fire-water

Scroll to Top